- The thinnest strain gauge type load cell in the world with a diameter of φ10 mm and a height of 2.3 mm
- Capacity 50 N/ 100 N/ 200 N/ 500 N
- As well as assembling to new machines, convenient for retrofitting to existing machines
- Suitable for load distribution measurement with multiple units
Specifications
Model | UST-50N | UST-100N | UST-200N | UST-500N |
---|---|---|---|---|
Rated capacity | 50 N | 100 N | 200 N | 500 N |
Rated output | Approx. 1 mV/V | |||
Safe overload | 150% R.C. | |||
Zero balance | ±20% R.O. | |||
Non-linearity | 0.7% or less R.O. | |||
Hysteresis | 0.7% or less R.O. | |||
Repeatability | 0.1% or less R.O. | |||
Compensated temperature range | 0 to +60℃ | |||
Safe temperature range | -10 to +70℃ | |||
Temperature effect on zero | 1% R.O/10℃ or below | |||
Temperature effect on span | 1% R.O/10℃ or below | |||
Input resistance | Approx. 350 Ω | |||
Output resistance | Approx. 350 Ω | |||
Recommended excitation voltage |
2.5 V | |||
Maximum excitation voltage |
5 V | |||
Insulation resistance (DC 50 V) |
1000 MΩ or more | |||
Cable | φ1.6 4-conductor shield cable (1 m) Cable end: 5 wires |
|||
Load cell material | Stainless steel | |||
Deflection at rated | 0.003 mm | 0.004 mm | 0.004 mm | 0.005 mm |
Natural frequency | 140 kHz | 160 kHz | 180 kHz | 180 kHz |
Weight | 2 g | |||
RoHS directives | 2011/65/EU (EU)2015/863 |
Example of use, Wiring diagram
External dimension
Download
Inquiry - UST (Compact Compression Type)