F850
Product outline
F850 is a mid-class loadcell indicator that can be used for wide-ranging applications from weighing scales requiring a high-level sequence such as hopper scales and packing scales to simple applications such as general platform scales.
F850 is a Bessel type low-pass filter that has high-speed A / S conversion and powerful digital processing capabilities of 100 times/sec and a strong attenuation characteristics. SI/FII interface allows easy construction of a network system to communicate with peripherals. F850 is a mid-class loadcell indicator that can be used for wide-ranging applications from weighing scales requiring a high-level sequence such as hopper scales and packing scales to simple applications such as general platform scales. F850X1 is a series controller equipped with a checker function.
Specifications
ANALOG SECTION|SETTING SECTION|INPUT / OUPUT SECTION|DISPLAY SECTION|GENERAL SPECIFICATIONS|OPTION|ACCESSORIES
ANALOG SECTION | |
Excitation voltage | 10V DC ±5%, Output current; within 120mA (Up to 4 units at 350Ω are parallel-connectable) |
---|---|
Zero adjustment range | 0 - approx. 2mV/V (digital adjustment) |
Gain adjustment range | 0.3 - 2.0mV/V (digital adjustment) |
Min. input sensitivity | 0.3μV / count |
Accuracy |
Non-linearity: within 0.01%/FS (Typ: 0.005%/FS at room temperature) Zero drift: within 0.1μV/°C RTI (Typ: 0.08μV/°C) Gain drift: within 15 ppm/°C (Typ: 5 ppm/°C) Noise: within 0.1μVp-p RTI (0.1 - 10 Hz) |
Analog filter | Bessel low-pass filter (-12dB/oct.), Selectable from 2, 4, 6, 8 Hz |
A/D converter |
Speed: 100 times/sec Resolution: 16 bit (binary) |
Min. display resolution | 1/10000 |
Secondary calibration | Calibration can be carried out without an actual load by connecting a resistor to one of the bridges of a loadcell. |
SETTING SECTION | |
Setting method |
・ Keyboard operation (keyboard with a key click buzzer) ・ External setting is available by installing RS-232C option |
---|---|
Setting value storage |
・ Initial set values: NOV RAM (Non-volatile RAM) ・ Other set values: C-MOS RAM with backup of a lithium battery (Effective for more than 7 years depending on usage conditions and storage environment) |
Setting value protection | Setting operation can be locked to prevent unauthorized modifications of default values and calibration by malfunction (LOCK) |
INPUT / OUPUT SECTION | |
External output signal | Transistor’s open collector output (Emitter = COM terminal); Output is LO when transistor is ON. |
---|---|
External input signal | ON when shorted to COM terminal by contact (relay, switch) or non-contact (transistor, open collector) |
Interface |
|
DISPLAY SECTION | |
Display unit | Numerical display with a character height of 17 mm by fluorescent display tube (8-digits) |
---|---|
Weight value display | 5 digits, Sign: Minus sign displayed on most significant digit |
Scale capacity | 5-digit numerical values (up to 99999) |
Character display | 5 x 7 dot matrix display, 24 digits x 2 lines ANK |
Unit display | 5 x 7 dot matrix display, 2-character selectable from t, kg, g, N, lb, none |
Display frequency | Selectable from 25, 13, 6, 3 times/sec (display only, system speed 100 times/sec) |
Min. scale division | 1 to 100 selectable |
Decimal point | Selectable from 0. 0.0, 0.00, 0.000 |
Center zero | True zero point (0±1/4 scale) or the center of each value is displayed. |
Message | Menus and guidance for settings are displayed. Operation status of the indicator is displayed when setting is not carried out. |
Status display | HOLD, ZALM, ZT, STAB, TARE, NET, GROSS, CZ, LOCK, NZ, SP1, SP2, SP3, UNDER, GO, OVER, LO, HI |
GENERAL SPECIFICATIONS | |
Power supply voltage | 85 - 110V, 102 - 132V, 170 - 220V, 187 - 242V AC (Please specify when ordering), 50/60 Hz |
---|---|
Power consumption | Approx. 15VA |
Operating conditions |
Temperature: Working temperature range -10°C - +40°C; Storage temperature range -40 - +80°C Humidity: 85% RH or less (non-condensing) |
External dimensions | 192 (W) x 96 (H) x 154 (D) [mm] (protruding parts not included), DIN standard size |
Panel cutout dimensions |
186 (W) x 92 (H) mm (+0.5 / -0) *Installation panel thickness: 1.6 mm or more |
Weight | Approx. 2.2 kg |
ACCESSORIES | |
Power supply cable (2 m) | 1 |
---|---|
Spare fuse (1A) | 1 |
Mini-driver for terminal block connection | 1 |
Loadcell connector | 1 |
Control signal connector | 1 |
F850 Operation Manual | 1 |
Option
Model | Interface |
232 | RS-232C communication interface |
---|
Optional accessories
Model | Description |
CAAC2P-P2 | AC input cord 2 m |
---|---|
CAAC3P-CEE7/7-P1.5 | AC input cord (withstand pressure: 250V) 1.5m |
CN3P-2P | 3P-2P conversion plug for AC input cord |
CA4131 | (6-core) cable with JR connector at one end (cable end is separated) 3 m |
CA4230 | JR-PRC conversion relay (6-core) cable 0.3 m |
CA4311 | JR-PRC conversion relay (6-core) 4-wire type / 6-wire type (for 520A) 1m |
CN22 | 57 series 50p connector for external I/O |
CN35 | D-Sub 25p connector for RS-232 |
LB01-NH |
Lithium battery (with NH connector) |
Inquiry - F850 (Weighing Indicator)