Product outline
Specifications
Analog section|Setting section|Interface|General specifications|Attachments
| Analog section | |
| Excitation voltage | DC 10 V±5%, Output current; within 120 mA, Remote sense type (Up to 4 load cells at 350 Ω are parallel-connectable.) |
|---|---|
| Zero adjustment range | 0 to approx. 2 mV/V |
| Gain adjustment range | 0.3 to 2.0 mV/V |
| Min. input sensitivity | 0.3 μV/count |
| Accuracy | Non-linearity: within 0.01% FS Zero drift: within 0.1 μV/°C RTI (Typ: 0.08 μV/°C) Gain drift: within 15 ppm/°C (Typ: 7 ppm/°C) |
| Analog filter | Bessel low-pass filter (-12 dB/oct.) selectable from 2, 4, 6, 8 Hz |
| A/D converter | Speed: 500 times/sec. Resolution: 16 bit |
| Min. display resolution | 1/10000 (Internally 1/40000) |
| Setting section | |
| Setting method | Setting by host on CC-Link or RS-232C interface, or setting by separately-sold remote console unit C110 or C120 |
|---|---|
| Setting value storage | ・ Initial setting values: NOV RAM (nonvolatile RAM) ・ Other setting values: C-MOS RAM with backup of a lithium battery * In either case above, rewrite can be locked. |
| Setting items | ・ Final, SP1, Before final, FF, over, under, high limit, Low limit, near zero, tare set ・ Compare inhibit time, judging time, complete output time, CPS feed time, auto zero times, judging times, FF CPS coefficient, average count of FF CPS, FF CPS ・ Select final and over/under comparison, select HI/LO limit comparison, select near zero comparison, discharge control mode, digital tare subtraction ON/OFF, FF CPS ON/OFF, complete signal output mode, over/under comparison mode, HI/LO limit comparison mode ・ Digital filter, motion detect (period), motion detect (range), zero tracking (period), zero tracking (range), analog filter, count of console display, SI/F gross/net select ・ Balance weight, capacity, min. scale division, net over, gross over, DZ regulation, decimal place, gravitational acceleration, set value LOCK (SOFT LOCK) ・ Simple comparison, select sequence mode, sequence mode CPS feed ON/OFF, sequence mode near zero check ON/OFF, sequence mode weight check ON/OFF, select external control input 0 – 4, select external control output 0 to 6 ・ tare, tare reset, digital zero, digital zero reset, sequence start/stop, sequence error reset, zero calibration, span calibration |
| External signal | ・ Input/output (14p amphenol type connector) ・ Input (5 points): ON when shorted to COM terminal ・ Output (7 points): Transistor’s open collector output; ON when transistor’s ON. Vceo = 30 V (max), Ic = 50 mA (max) |
| Interface | |
| CC-Link | Field network to link with Mitsubishi’s PLC Transmission medium: 3-wire type (with shield) Transmission rate: Selectable from 156 k/ 625 k/ 2.5 M/ 5 M/ 10 M bps |
|---|---|
| RS-232C | Write / read weight data, various statuses and setting values via commands from host computer (Exclusive use with setting remote console unit, C110 or C120) Specification: RS-232C conformance, Transmission mode: Full duplex, asynchronous Transfer rate: 1200/ 2400/ 4800/ 9600/ 19200/ 38400 bps Format: Data length: 7/8 bit Stop bit length: 1/2 bit Parity bit: Odd/ even/ none |
| SI/F | 2-wire type serial interface. This is an interface to connect to Unipulse printers, external display units, etc. Transmission mode: Asynchronous, Transfer rate: 600 bps |
| General specifications | |
| Power supply voltage | AC 100 to 240 V(+10% -15%) (Free power supply 50/60 Hz) |
|---|---|
| Power consumption | 13.0/12.5 VA (Rating: 100 V) |
| Operating conditions | Working temperature range: -10°C to +40°C; Storage temperature range: -20 to +80°C Humidity: 85% RH or less (non-condensing) |
| Dimensions | 67(W) × 185(H) × 130(D) mm (Not including projections) |
| Weight | Approx. 1.7 kg |
| Attachments | |
| AC input cable (3 m) | 1 |
|---|---|
| Spare fuse (0.5 A) | 1 |
| Load cell input connector | 1 |
| 57 series 14p connector for external I/O | 1 |
| RS-232C connector | 1 |
| CC-Link connector | 1 |
| Terminal block connection driver | 1 |
| Wall anchor | 1 |
| Crimping terminal | 3 |
| Operation manual | 1 |
Optional accessories
| Model | |
| C110 | Setting remote console unit, 4 keys, Cable length 0.5 m |
|---|---|
| C120 | Setting remote console unit, 12 keys, Cable length 0.5 m |
| CAAC2P-B3 | AC input cord 3 m |
| CAAC3P-CEE7/7-B2 | AC input cord (withstand voltage: 250 V) 2 m |
| CA38X11 | Mini DIN-D-Sub 25p crossing cable 1 m |
| CN20 | 57 series 14p connector for external I/O |
| CN61 | Round DIN 8p connector for RS-232C |
| CN71 | CC-Link connector |
| CA4131 | (6-core) cable with JR connector at one end (cable end is separated) 3 m |
| CA4230 | JR-PRC conversion relay (6-core) cable 0.3 m |
| CA4311 | JR-PRC conversion relay (6-core) 4-wire type / 6-wire type (for 520 A) 1 m |

Please note that there are possibilities of individual differences in a color tone on display devices such as LEDs, fluorescent display tubes and LCDs due to manufacturing process or production lots.
Structure of product code

Inquiry - F156 (Weighing Indicator)