★Transmission Parts-Ball screw, It transmits through the ball involving in the locknut and screw to reach the accuracy and longer operation lifetime.
★Material-Aluminum Alloy
| Model No. | Specification | Value |
|---|---|---|
| AX60-A2OP | Table Size (mm) | 60 × 60 |
| AX60-A2OP | Travel Stroke (mm) | 20 |
| AX60-A2OP | Drive Type | Ball Screw Ø6,lead 1mm |
| AX60-A2OP | Rail | Crossed-roller Bearing |
| AX60-A2OP | Stage Material / Surface Treatment | Aluminum Alloy / Black anodized |
| AX60-A2OP | Main Unit Weight (Kgs) | 0.64 |
| AX60-A2OP | Coupling | FAMS16-5*5 |
| AX60-A2OP | Accuracy Level | OP:Ultra Precision |
| AX60-A2OP | Wiring Method | R : Right wiring (Standard);L : Left wiring |
| AX60-A2OP | Resolution(Pulse) (µm) | M: 2.5 (Full);1.25 (Half) / J: 5 (Full);2.5 (Half) |
| AX60-A2OP | Max. Speed(Full Step) (mm/sec) | 10 |
| AX60-A2OP | Positioning Precision (µm) | 5 |
| AX60-A2OP | Repeatability Precision(µm) | ±0.3 |
| AX60-A2OP | Load Capacity (Kgf) | 6 |
| AX60-A2OP | Missed Step (µm) | 1 |
| AX60-A2OP | Moment Stiffness | Pitch: 0.18 / Yaw: 0.14 / Rolling: 0.1 ("/N-cm) |
| AX60-A2OP | Pitch / Yaw | Pitch: < 20" / Yaw: < 15" |
| AX60-A2OP | Parallelism (µm) | 30 |
| AX60-A2OP | Dynamic Straightness (µm) | 3 |
| AX60-A2OP | Dynamic Parallelism (µm) | 6.6 |
| AX60-A2OP | Motor - Type / Shaft Numbers | M: 5-phase stepper high-resolution motor / ☐28 double shafts; J: 5-phase stepper motor / ☐28 double shafts |
| AX60-A2OP | Motor - Brand / Model | M: Orientalmotor / PK523HPMB; J: Orientalmotor / PKP523N12B |
| AX60-A2OP | Driver Brand / Model | Orientalmotor / CVD Series - 5 Phase stepping motor (Additional options) |
| AX60-A2OP | Stage Side Connector | 15-Pin male end connetor D-SUB / 12-Pin male end connetor HRS |
| AX60-A2OP | Controller Side Connector | 15-Pin female end connetor D-SUB (Additional options) / 12-Pin female end connetor HRS (Additional options) |
| AX60-A2OP | Origin Sensor | Photoelectric sensor GMT-sensor |
| AX60-A2OP | Limit Sensor | N/A |
| AX60-A2OP | Power Voltage | 24V±10% |
| AX60-A2OP | Control Output | NPN open collector output under 24V 8mA |
| AX60-A2OP | Output Control | Testing (sensing):output transistor OFF (closed) |
| Multi-point repeated positioning accuracy |
|
♦ Accuracy measurement description 1. Unidirectional positioning accuracy: within the range of the predetermined detection stroke, starting from a starting position, moving and positioning in a certain direction sequentially, and detecting the actual ♦ Precision introduction 1. Design the GMT high-level precision inspection method to meet the precision requirements of fiber coupling and semiconductor manufacturing process.
|
| System Configuration Diagram |
|
♦ For detailed specifications, please read the description for the stage and connecting cable. ♦ For selection of driver, please refer to the cross-reference table for the motor/driver of the standard motorized stage or the GMT motor and driver catalog. ♦ The most preferred driver is recommended to be specified by GMT as considerations. For different needs, please choose the suitable driver based on real functional needs.
|
| Axis Definition |
|
GMT has defined different axis as the following figuration according to the movement direction: Horizontal movement direction is X and Y axis. Vertical movement direction is Z axis. Movement around X, Y, Z axis is defined to α axis, β axis, and θ axis. Green arrows present the specified axis movement direction.
|
Inquiry - AX60 - Ultra Precision