TM100C32RN


This product is part of the Easy modicon M100 range, an offer of logic controllers for simple machines up to 40 I/O. This logic controller provides 4 fast inputs, 2 high speed inputs, 14 regular inputs and 12 normally opened relay outputs. It is an Easy Modicon logic controller with an input voltage of 24V DC, an output voltage of 24V DC, 220V AC and an output current of 2A. Easy to maintain and update with its micro SD memory card. Integrated connections are USB port with mini B USB 2.0 connector, non isolated serial link 1 and RS485 interface and non isolated serial link 2 and RS232/RS485 interface. It is a controller with an internal flash of 512KB and a micro SD card capacity of 32GB. It is an IP20 rated product. Its dimensions are 175mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.409kg. Designed for automation of small finishing, production, assembly or packaging machines. This product is certified by CE. It meets EN/IEC 61010-2-201 and EN/IEC 61131-2 standards. It supports DIN rail mount. Entry-level plc perfectly suited to meet specific needs of emerging markets at an affordable price without compromise. Cost-effective and easy solution to sequential control needs for your simple machines up to 40 I/O.

Main
Range of product: Easy Modicon M100
Product or component type: Logic controller
[Us] rated supply voltage: 100...240 V AC
Discrete I/O number: 32
Discrete input number: I2...I5: 4 fast input; I0...I1: 2 high speed input; I6...I19: 14 regular input
Discrete output number: 12 relay
Discrete input voltage: 24 V
Discrete input voltage type: DC
Discrete input current: 7 mA for regular input; 7 mA for fast input; 9 mA for high speed input
Discrete output voltage: 24 V DC; 220 V AC
Discrete output current: 2 A
Discrete output type: Relay normally open
Power consumption in VA: 32…44 VA at 100...240 V AC (with max I/O)


Complementary
Supply voltage limits: 85…264 V
Voltage state 1 guaranteed: >= 15 V for input
Voltage state 0 guaranteed: <= 5 V for input
Network frequency: 50/60 Hz
Inrush current: 50 A
Input impedance: 3.3 kOhm for regular input; 3.3 kOhm for fast input; 2.81 kOhm for high speed input
Response time: 35 µs turn-on, I2...I5 terminal(s) for fast input; 100 µs turn-off, I2...I5 terminal(s) for fast input; 5 µs turn-on, I0...I1 terminal(s) for high speed input; 5 µs turn-off, I0...I1 terminal(s) for high speed input; 35 µs turn-on, I6...I13 terminal(s) for regular input; 100 µs turn-off, I6...I13 terminal(s) for regular input; 10 ms turn-on, Q0...Q11 terminal(s) for relay output; 10 ms turn-off, Q0...Q11 terminal(s) for relay output; 55 µs turn-on, I14...I19 terminal(s) for regular input; 125 µs turn-off, I14...I19 terminal(s) for regular input
Configurable filtering time: 0 ms for input; 3 ms for input; 12 ms for input
Output voltage limits: 30 V DC; 250 V AC
Maximum current per output common: 4 A at COM 0; 4 A at COM 1; 4 A at COM 2
Electrical durability: 100000 cycles AC-12, 240 V, 480 VA, resistive; 100000 cycles DC-12, 24 V, 48 W, resistive
Switching frequency: 0.1 Hz with maximum load; 5 Hz without maximum load
Mechanical durability: 20000000 cycles for relay output
Minimum load: 10 mA at 5 V DC for relay output
Memory capacity: 1024 kB internal flash with 10000 instructions for backup of programs
Data storage equipment: 32 GB micro SD card (optional)
Execution time for 1 KInstruction: 0.3 ms for event and periodic task
Execution time per instruction: 0.2 µs Boolean
Exct time for event task: 60 µs response time
Regulation loop: Adjustable PID regulator up to 14 simultaneous loops
Control signal type: Quadrature (x1, x2, x4) at 60 kHz for fast input (HSC mode); Pulse/direction at 60 kHz for fast input (HSC mode); Single phase at 60 kHz for fast input (HSC mode); CW/CCW at 60 kHz for fast input (HSC mode)
Counting input number: 2 fast input (HSC mode) at 60 kHz 32 bits
Integrated connection type: USB port with mini B USB 2.0 connector; Non isolated serial link serial 1 with terminal block connector and RS485 interface; Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
Transmission rate: 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485; 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232; 12 Mbit/s for USB
Communication port protocol: USB port: USB - SoMachine-Network; Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
Local signalling: 1 LED (green) for PWR; 1 LED (green) for RUN; 1 LED (red) for module error (ERR); 1 LED (green) for SD card access (SD); 1 LED (green) for SL1; 1 LED per channel (green) for I/O state
Electrical connection: removable screw terminal block for inputs; removable screw terminal block for outputs; removable screw terminal block, 4 terminal(s) for connecting the serial link1; Mini B USB 2.0 connector for a programming terminal; removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply
Maximum cable distance between devices: Shielded cable: <10 m for fast input; Shielded cable: <10 m for high speed input; Unshielded cable: <150 m for output; Unshielded cable: <50 m for regular input
Insulation: Between input and internal logic at 560 V AC; Between fast input and internal logic at 560 V AC; Between input groups at 560 V AC; Non-insulated between inputs; Between output and internal logic at 1780 V AC; Between output groups at 1780 V AC; Between supply and internal logic at 1780 V AC
Sensor power supply: 24 V DC
Mounting support: Top hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715
Height: 90 mm
Depth: 70 mm
Width: 175 mm
Net weight: 0.435 kg


Environment
IP degree of protection: IP20 with protective cover in place
Product certifications: CE
Standards: EN/IEC 61010-2-201; EN/IEC 61131-2
Electromagnetic compatibility: Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2; Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to EN/IEC 61000-4-3; Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011; Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011; Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011; Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011; Magnetic field at power frequency - test level: 30 A/m (I/O) conforming to EN/IEC 61000-4-8; Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4; 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 0.5 kV class A (power lines (DC)) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV class A (power lines (AC)) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV (relay output) conforming to EN/IEC 61000-4-5; Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
Shock resistance: 15 gn for 11 ms; 30 gn for 6 ms
Immunity to microbreaks: 10 ms
Vibration resistance: 3.5 mm at 5…8.4 Hz on symmetrical rail; 1 gn at 8.4…150 Hz on symmetrical rail; 3.5 mm at 5…8.4 Hz on panel mounting; 3 gn at 8.4…150 Hz on panel mounting
Relative humidity: 10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage)
Ambient air temperature for operation: 0…55 °C (horizontal installation)
Ambient air temperature for storage: -25…70 °C
Pollution degree: <= 2
Operating altitude: 0...2000 m
Storage altitude: 0…3000 m


Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 9.312 cm
Package 1 Width: 13.703 cm
Package 1 Length: 18.69 cm
Package 1 Weight: 640.0 g
Unit Type of Package 2: S03
Number of Units in Package 2: 12
Package 2 Height: 30.0 cm
Package 2 Width: 30.0 cm
Package 2 Length: 40.0 cm
Package 2 Weight: 8.036 kg
Unit Type of Package 3: P12
Number of Units in Package 3: 288
Package 3 Height: 95.0 cm
Package 3 Width: 80.0 cm
Package 3 Length: 120.0 cm
Package 3 Weight: 132.0 kg


Dimensions Drawings


 



 Inquiry - Controller M100 - 20I/12O relay - 220VAC (TM100C32RN)