Language: EN | δΈ­ζ–‡ |

Share:


Schneider Tesys 3P 3NO 18A Contactor LC1D18M7



 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 220 V AC coil
LC1D18M7


TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 18A/690V AC-3/3e (7.5kW@400V). It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Main Characteristics
  • Range of product: TeSys Deca
  • Product or component type: Contactor
  • Device short name: LC1D
  • Contactor application: Resistive load, Motor control
  • Utilisation category: AC-3, AC-3e, AC-1, AC-4
  • Poles description: 3P (3 NO pole contact composition)
  • Rated operational voltage ([Ue]):
    Power circuit:  ≤690 V AC 25...400 Hz
    Power circuit:  ≤300 V DC
  • Rated operational current ([Ie]):
    • 18 A (at <60 °C) at ≤440 V AC AC-3 / AC-3e for power circuit<60
    • 32 A (at <60 °C) at ≤440 V AC AC-1 for power circuit<60
  • Control circuit voltage ([Uc]): 220 V AC 50/60 Hz
 
 

Complementary Specifications & Ratings

  • Motor power:
    • 4 kW at 220/230 V, 7.5 kW at 380/400 V, 9 kW at 415/440 V, 10 kW at 500/690 V AC (AC-3 / AC-3e)
    • 4 kW at 400 V AC (AC-4)
  • Thermal & Short-Time Current:
    • Conventional free air thermal current ([Ith]): 32 A (at 60 °C) for power circuit / 10 A (at 60 °C) for signalling circuit
    • Rated making capacity (Irms): 300 A at 440 V for power circuit
    • Short-time withstand current ([Icw]): 145 A (10 s), 240 A (1 s), 84 A (1 min), 40 A (10 min) at 40 °C for power circuit
  • Durability & Reliability:
    • Mechanical durability: 15 Mcycles
    • Electrical durability: 1.65 Mcycles (18 A AC-3 / AC-3e); 1 Mcycles (32 A AC-1)
    • Safety reliability level: B10d = 1,369,863 cycles (nominal load) / 20,000,000 cycles (mechanical load)
  • Control Circuit & Power Consumption:
    • Inrush power: 70 VA at 50/60 Hz ( 0.75)cosΟ•
    • Hold-in power: 7 VA at 50 Hz / 7.5 VA at 60 Hz ( 0.3)cosΟ•
    • Operating time: 12...22 ms closing / 4...19 ms opening
  • Auxiliary Contacts: 1 NO + 1 NC configuration
  • Dimensions & Weight:
    • Height: 77 mm, Width: 45 mm, Depth: 86 mm
    • Net weight: 0.33 kg
 
Environment & Compliance
  • Standards: EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 14
  • Product certifications: UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme
  • IP degree of protection: IP20 front face conforming to IEC 60529
  • Ambient air temperature:
    • Operation: -40…60 °C (60…70 °C with derating)
  • Contractual warranty: 18 months

Dimensions Drawings
Dimensions



(1) Including LAD 4BB
(2) Minimum electrical clearance

 
Dimension Configuration LC1 D09…D18 LC1 D093…D123 LC1 D099…D129
b Without add-on blocks 77 99 80
b1 With LAD 4BB 94 107 95.5
  With LA4 D2 110¹ 123¹ 111.5¹
  With LA4 DF, DT 119¹ 132¹ 120.5¹
  With LA4 DW, DL 126¹ 139¹ 127.5¹
c Without cover or add-on blocks 84 84 84
  With cover, without add-on blocks 86 86 86
c1 With LAD N or C (2 or 4 contacts) 117 117 117
c2 With LA6 DK10, LAD 6K10 129 129 129
c3 With LAD T, R, S 137 137 137
  With LAD T, R, S and sealing cover 141 141 141


Connections and Schema
Wiring

  

Specifications

Sorry, currently do not have any product specifications
Sorry, currently do not have any video uploaded.
Sorry, currently do not have any file for download.