Share:


Schneider Tesys D 1NO + 1NC Auxiliary Contact Block LADN11



TeSys D - auxiliary contact block - 1 NO + 1 NC - screw-clamps terminals
LADN11


TeSys Deca instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD. It provides 1NO+1NC contacts (NC mirror certified) rated up to 10A/690V AC, connection by screw clamp terminals. Clip-on front mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC), Sustainability compliant.

Main
  • Range:
    • TeSys
    • TeSys Deca
  • Product name: TeSys Deca
  • Product or component type: Auxiliary contact block
  • Device short name: LADN
  • Range compatibility:
    • TeSys D CAD
    • TeSys D LC1D
    • TeSys F LC1F
    • TeSys F CR1F
    • TeSys Deca CAD
    • TeSys Deca LC1D
  • Mounting location: Front
  • Pole contact composition: 1 NO + 1 NC
  • Contacts operation: Instantaneous
  • [Ue] rated operational voltage: 690 V AC 25...400 Hz
  • [Ie] rated operational current:
    • 6 A at 120 V AC-15
    • 1.04 A at 690 V AC-15
    • 0.55 A at 125 V DC-13
    • 0.1 A at 600 V DC-13
  • [Ui] rated insulation voltage:
    • 690 V conforming to IEC 60947-5-1
    • 600 V conforming to UL
    • 600 V conforming to CSA
  • [Ith] conventional free air thermal current: 10 A (at 60 °C)
  • Standards:
    • EN/IEC 60947-5-1
    • GB/T 14048.5
    • EN 50012
    • UL 60947-5-1
    • CSA C22.2 No 60947-5-1
    • IEC 60335-1:Clause 30.2
    • IEC 60335-2-40:Annex JJ
    • UL 60335-2-40:Annex JJ
  • Product certifications:
    • CB Scheme
    • UL
    • CSA
    • CCC
    • EAC
    • UKCA
 
Complementary
  • Irms rated making capacity:
    • 140 A AC conforming to IEC 60947-5-1
    • 250 A DC conforming to IEC 60947-5-1
  • Permissible short-time rating:
    • 100 A 60 °C 1 s
    • 120 A 60 °C 500 ms
    • 140 A 60 °C 100 ms
  • Protection type: GG fuse 10 A
  • Mechanical durability: 30 Mcycles
  • Minimum switching current: 5 mA
  • Minimum switching voltage: 17 V
  • Non-overlap time:
    • 1.5 ms on de-energisation no overlap between NC and NO contact
    • 1.5 ms on energisation no overlap between NC and NO contact
  • Insulation resistance: > 10 MOhm
  • Connections - terminals:
    • Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
    • Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
    • Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
    • Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
    • Screw clamp terminals 1 cable(s) 1…4 mm²rigid without cable end
    • Screw clamp terminals 2 cable(s) 1…4 mm²rigid without cable end
  • Tightening torque:
    • 1.7 N.m - with screwdriver flat Ø 6 mm
    • 1.7 N.m - with screwdriver Philips No 2
    • 1.7 N.m - with screwdriver pozidriv No 2
  • Height: 48 mm
  • Width: 26 mm
  • Depth: 42 mm
  • Colour: Dark grey
 
Environment
  • Environmental characteristic: Normal environment
  • IP degree of protection: IP20 conforming to IEC 60529
  • Protective treatment: TH conforming to IEC 60068
  • Ambient air temperature for storage: -60…80 °C
  • Ambient air temperature for operation: -5…60 °C
  • Operating altitude: 3000 m
 
Packing Units
Package 1
  • Unit Type of Package: PCE
  • Number of Units: 1
  • Package Height: 3 cm
  • Package Width: 4.2 cm
  • Package Length: 5.3 cm
  • Package Weight: 34 g
Package 2
  • Unit Type of Package: S03
  • Number of Units: 320
  • Package Height: 30 cm
  • Package Width: 30 cm
  • Package Length: 40 cm
  • Package Weight: 11.452 kg
Package 3
  • Unit Type of Package: P06
  • Number of Units: 2560
  • Package Height: 75 cm
  • Package Width: 60 cm
  • Package Length: 80 cm
  • Package Weight: 99 kg


 Inquiry - Schneider Tesys D 1NO + 1NC Auxiliary Contact Block LADN11