Product outline
Hardly any interference from torsion & less impact on accuracy due to lateral load too!
Easy-to-install threaded-type with male screws is newly released!
● Capacity 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN
● As threaded with male screws on both ends,
and low-profile nuts come with, it’s easy to mount by double nut
● Measure both tension & compression load
● The height is short as 40 to 92 mm;
this load cell does not block other equipment
(1 to 5kN: 40 mm, 10 to 20kN: 70 mm, 50kN-S:70 mm, 50kN:92 mm)
Installation example

Installation method
Specifications
■UIS-1KN、UIS-2KN、UIS-5KN
| Specification | UIS-1KN | UIS-2KN | UIS-5KN |
|---|---|---|---|
| Rated capacity | 1 kN | 2 kN | 5 kN |
| Rated output | Approx. 1.0 mV/V | — | — |
| Safe overload | 300% R.C. | — | — |
| Zero balance | ±10% R.O. | — | — |
| Non-linearity | 0.2% or less R.O. | — | — |
| Hysteresis | 0.2% or less R.O. | — | — |
| Repeatability | 0.1% or less R.O. | — | — |
| Compensated temperature range | -10 to +60℃ | — | — |
| Safe temperature range | -20 to +70℃ | — | — |
| Temperature effect on zero | 0.5% R.O./10℃ or below | — | — |
| Temperature effect on span | 0.5% R.O./10℃ or below | — | — |
| Input resistance | Approx. 1000 Ω | — | — |
| Output resistance | Approx. 1000 Ω | — | — |
| Recommended excitation voltage | 5 V | — | — |
| Maximum excitation voltage | 7.5 V | — | — |
| Insulation resistance (DC 50 V) | 1000 MΩ or more | — | — |
| Cable | φ2.5 6-conductor flexible cable (3 m); Cable end: 7 wires | — | — |
| Load cell material | Stainless steel | — | — |
| Deflection at rated | 0.015 mm | 0.014 mm | 0.021 mm |
| Natural frequency | 2 kHz | 3 kHz | 5 kHz |
| Weight | Approx. 30 g | — | — |
■UIS-10KN、UIS-20KN、UIS-50KN、UIS-50KN-S
| Specification | UIS-10KN | UIS-20KN | UIS-50KN | UIS-50KN-S |
|---|---|---|---|---|
| Rated capacity | 10 kN | 20 kN | 50 kN | 50 kN |
| Rated output | Approx. 1.0 mV/V | — | — | — |
| Safe overload | 300% R.C. | — | — | — |
| Zero balance | ±10% R.O. | — | — | — |
| Non-linearity | 0.2% or less R.O. | — | — | — |
| Hysteresis | 0.2% or less R.O. | — | — | — |
| Repeatability | 0.1% or less R.O. | — | — | — |
| Compensated temperature range | -10 to +60℃ | — | — | — |
| Safe temperature range | -20 to +70℃ | — | — | — |
| Temperature effect on zero | 0.5% R.O./10℃ or below | — | — | — |
| Temperature effect on span | 0.5% R.O./10℃ or below | — | — | — |
| Input resistance | Approx. 1000 Ω | — | — | — |
| Output resistance | Approx. 1000 Ω | — | — | — |
| Recommended excitation voltage | 5 V | — | — | — |
| Maximum excitation voltage | 7.5 V | — | — | — |
| Insulation resistance (DC 50 V) | 1000 MΩ or more | — | — | — |
| Cable | φ5 6-conductor flexible cable (3 m); Cable end: 7 wires | — | — | — |
| Load cell material | Stainless steel | — | — | — |
| Deflection at rated | 0.025 mm | 0.040 mm | 0.070 mm | 0.050 mm |
| Natural frequency | 15 kHz | 15 kHz | 13 kHz | 16 kHz |
| Weight | Approx. 100 g | Approx. 100 g | Approx. 260 g | Approx. 210 g |
Attachments
・Low-profile nuts (for loosening prevention) ×2

Optional accessories
・Low-profile spanner ×1

Wiring diagram

External dimension

Inquiry - UIS (Compact Compression Type)