Product outline
Compact and thin design allows easy mounting on existing equipment.
● Capacity 30 kN/ 50 kN/ 100 kN/ 200 kN/ 300 kN/ 500 kN
● Stainless steel
● Compact and thin design allows easy mounting on existing equipment.
Specifications
Model | UNBF2-30KN, UNBF2-50KN, UNBF2-100KN, UNBF2-200KN, UNBF2-300KN, UNBF2-500KN |
---|---|
Rated capacity | 30 kN, 50 kN, 100 kN, 200 kN, 300 kN, 500 kN |
Rated output | 2 mV/V±0.5% |
Safe overload | 150% R.C. |
Zero balance | ±10% R.O. |
Non-linearity | 0.35% or less R.O. |
Hysteresis | 0.35% or less R.O. |
Repeatability | 0.20% or less R.O. |
Compensated temperature range |
-10 to +60℃ |
Safe temperature range | -20 to +70℃ |
Temperature effect on zero |
0.1% R.O./10℃ or below |
Temperature effect on span |
0.1% R.O./10℃ or below |
Input resistance | Approx. 400 Ω |
Output resistance | Approx. 350 Ω |
Recommended excitation voltage |
10 V |
Maximum excitation voltage |
20 V |
Insulation resistance (DC 50 V) |
1000 MΩ or more |
Cable | φ8 4-conductor flexible cable 3 m Cable end : 5 wires |
Cable color code | +EXC: Red +SIG: White -EXC: Blue -SIG: Black SHIELD: Yellow |
Load cell material | Stainless steel |
Deflection at rated | 30KN:0.130 mm 50KN:0.140 mm 100KN:0.160 mm 200KN:0.200 mm 300KN:0.250 mm 500KN:0.350 mm |
Natural frequency | 30KN:9 kHz 50KN:12 kHz 100KN:17 kHz 200KN:9.4 kHz 300KN:8.9 kHz 500KN:6.2 kHz |
Weight | 30KN:1.6 kg 50KN:1.6 kg 100KN:1.6 kg 200KN:3.9 kg 300KN:6.3 kg 500KN:11 kg |
RoHS directives | 2011/65/EU (EU)2015/863 |
Application example, Wiring diagram
External dimension
Download
Inquiry - UNBF2