SANUPS N11D-Li - Passive Standby (UPS)



SANUPS N11D-Li
Standby UPS with 200% overload capacity and lithium-ion battery

 

Features
200% Overload Capacity―Twice the Rated Capacity

Delivers 200%  overload capacity, even during battery operation. Ideal for equipment with large power fluctuations,such as elevators, robots, and motor-driven machinery.

High Efficiency, Energy Savings, and Low Noise
Achieves power conversion efficiency of up to 98.6%, reducing power consumption and CO2 emissions while supporting the achievement of the SDGs.
Low operating noise of approximately 30 dB  supports installation in noise-sensitive environments.


Long Life
The UPS uses lithium-ion batteries. It can operate for 10 years without battery replacement, reducing the maintenance work and costs.

Wide Operating Temperature Range
The UPS operates over a wide temperature range of 0 to +55°C, providing greater installation flexibility in environments with large temperature variations.

Flexible Product Lineup
Slim design supports wall mounting, enabling installation in control panels and other equipment. Two floor-standing installation options are also available to suit various installation conditions.
The battery unit can be installed separately from the UPS unit, providing greater flexibility for a wide range of applications and installation layouts.






Installation examples
This UPS consists of a UPS unit and a battery unit. Battery units are available in different capacities and sizes depending on the required backup time. The order no. indicates the combination of UPS unit and battery unit(s).

 

(1) 

For 1 s

(2) 

In a 3 kVA configuration

(3) 

In normal operation at rated load level

(4) 

At a 25ºC ambient temperature

 

Lineup




Load Level vs Backup Time


Note: Reference value at 25ºC ambient temperature and load power factor of 0.8, using new, fully charged batteries.



Applications
Commercial elevators, high speed doors, tower fan, cold storage, and semiconductor manufacturing equipment

 

Model no.
 

UPS topology
 

No. of input phases/wires
 

Rated input voltage[V]
 

No. of output phases/wires
 

Rated output capacity[kVA]
 

Rated output capacity[kW]
 

Rated output voltage[V]
 

Standard backup time[min]
 

S-N11DL202AFS

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

2

1.6

200/208/220/230

9

S-N11DL202AFT

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

2

1.6

200/208/220/230

9

S-N11DL202AWT

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

2

1.6

200/208/220/230

9

S-N11DL302AFS

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

3

2.4

200/208/220/230

8

S-N11DL302AFT

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

3

2.4

200/208/220/230

8

S-N11DL302AWT

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

3

2.4

200/208/220/230

8

 

Model no.
 

UPS topology
 

No. of input phases/wires
 

Rated input voltage[V]
 

No. of output phases/wires
 

Rated output capacity[kVA]
 

Rated output capacity[kW]
 

Rated output voltage[V]
 

Standard backup time[min]
 

S-N11DL202AFS

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

2

1.6

200/208/220/230

9

S-N11DL202AFT

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

2

1.6

200/208/220/230

9

S-N11DL202AWT

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

2

1.6

200/208/220/230

9

S-N11DL302AFS

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

3

2.4

200/208/220/230

8

S-N11DL302AFT

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

3

2.4

200/208/220/230

8

S-N11DL302AWT

Passive standby

Single-phase 2-wire

200/208/220/230

Single-phase 2-wire

3

2.4

200/208/220/230

8

 