SANUPS A22A - Double Conversion Online (UPS)



SANUPS A22A
Highly Reliable Online UPS

Lineup



Features
High Efficiency

This UPS achieves a high efficiency of 94.5%. This reduces running costs and contributes to energy savings.

Flexible System Configuration
5 kVA modules allow users to select the output capacity to match the needs of the application.



High Reliability
The double conversion online topology ensures a continuous supply of stable high quality power.
Parallel redundant operation further improves the reliability of the power supply.


Wide Input Voltage Range
This UPS has a wide input voltage range of 240 to 460 V(1) and a wide input frequency range of 46 to 54 Hz(2).
This prevents unnecessary battery operation, minimizing battery drain.

(1) The input voltage range when the rated input voltage is set to 400 V.
(2) The input frequency range when the rated input frequency is set to 50 Hz.


Easy Maintenance
Front-access design allows users to install and remove batteries and inverter modules easily.
Maintenance can be performed without interrupting the inverter power to critical loads during parallel redundant operation. In addition, power can continue to be supplied even if an outage occurs during maintenance.


Operating Panel



Circuit Block Diagram



Load Level vs Backup Time




Applications
Server and network equipment, data center equipment, factory facilities, and power equipment

 

Model no.                            
 

Product name                            
 

UPS topology                            
 

No. of input phases/wires
 

Rated input voltage[V]
 

No. of output phases/wires
 

Rated output capacity[kW]                            
 

Rated output capacity[kVA]                            
 

Rated output voltage[V]
 

Energy storage device type
 

Standard backup time[min]                            
 

Protection rating
 

A22A502B001E (200V)

SANUPS A22A Inverter Module

Double conversion online

3-phase 4-wire

380/400/415

Single-phase 2-wire

5

5

220/230/240

 

10

 

A22A502B001E (400V)

SANUPS A22A Inverter Module

Double conversion online

3-phase 4-wire

380/400/415

3-phase 4-wire

5

5

380/400/415

 

10

 

BCA22AA00E

SANUPS A22A Battery Module

 

 

 

 

 

 

 

 

 

 

BPA22AA00E

SANUPS A22A Battery Pack

 

 

 

 

 

 

 

 

 

 

PDA22AS04NB001E

SANUPS A22A 4-Unit Cabinet (Half size)

 

 

 

Single-phase 2-wire

 

5 ~ 20

220/230/240

 

 

 

PDA22AS07NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

Single-phase 2-wire

 

5 ~ 55

220/230/240

 

 

 

PDA22AS14NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

Single-phase 2-wire

 

5 ~ 55

220/230/240

 

 

 

PDA22AS21NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

Single-phase 2-wire

 

5 ~ 55

220/230/240

 

 

 

PDA22AS28NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

Single-phase 2-wire

 

5 ~ 55

220/230/240

 

 

 

PDA22AS35NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

Single-phase 2-wire

 

5 ~ 55

220/230/240

 

 

 

PDA22AS42NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

Single-phase 2-wire

 

5 ~ 55

220/230/240

 

 

 

PDA22AT04NB001E

SANUPS A22A 4-Unit Cabinet (Half size)

 

 

 

3-phase 4-wire

 

5 ~ 20

380/400/415

 

 

 

PDA22AT07NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

3-phase 4-wire

 

5 ~ 35

380/400/415

 

 

 

PDA22AT14NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

3-phase 4-wire

 

40 ~ 105

380/400/415

 

 

 

PDA22AT21NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

3-phase 4-wire

 

40 ~ 105

380/400/415

 

 

 

PDA22AT28NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

3-phase 4-wire

 

40 ~ 105

380/400/415

 

 

 

PDA22AT35NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

3-phase 4-wire

 

40 ~ 105

380/400/415

 

 

 

PDA22AT42NB001E

SANUPS A22A 7-Unit Cabinet

 

 

 

3-phase 4-wire

 

40 ~ 105

380/400/415

 

 

 

 

 



 Inquiry - SANUPS A22A - Double Conversion Online (UPS)